Sign In | Join Free | My qualitytoyschina.com
China XI'AN BEICHENG ELECTRONICS CO.,LTD logo
XI'AN BEICHENG ELECTRONICS CO.,LTD
The Best Quality, The Best Service!
Site Member

5 Years

Home > VICTOR Digital Multimeter >

Digital Pocket Analog Multimeter 10A 1000V With Resistance Function

XI'AN BEICHENG ELECTRONICS CO.,LTD
Contact Now

Digital Pocket Analog Multimeter 10A 1000V With Resistance Function

Brand Name : VICTOR

Model Number : VC3010

Certification : CE

Place of Origin : CHINA

MOQ : 100pcs

Payment Terms : T/T, Western Union, L/C, Paypal

Supply Ability : 10000pcs available

Delivery Time : 5 to 30 days

Packaging Details : Color box , 50pcs/Carton, 22.4KG/Carton

Price : USD8/pc

Size : 150mm*100mm *38mm

Product Name : Analog Multimeter

Model No. : VC3010

Product Packing : Color box

Packing Details : 50pcs/Carton; Carton Size:46.4*31.5*51

Brand : VICTOR

Contact Now

Digital Pocket Analog Multimeter 10A 1000V With Resistance Function

VC3010 Analog Multimeter Large Lcd Display 1000V 10A 10kΩ

SAFETY INFORMATION

  1. Never use meter on the electric circuit that exceed 3kVA.
  2. Pay special attention when measuring the voltage of AC30 Vrms or DC 60V or more to avoid injury.
  3. Never apply an input signals exceeding the maximum rating input value.
  4. Never user meter for measuring line connected with equipment (i.e. motors) that generates induced or surge voltage since it may exceed the maximum allowable voltage.
  5. Never use meter if the meter or test leads are damaged or broken.
  6. To ensure safety and maintain accuracy, calibrate and check the meter at least once a year.
  7. Never use uncased meter
  8. Be sure to use a fuse of the specified rating or type. Never use a substitute of the fuse or never made a short circuit of the fuse.
  9. Always keep your fingers behind the finger guards on the probe when making measurements.
  10. Be sure to disconnect the test pins from the circuit when changing the function or range.
  11. Before starting measurement, make sure that the function and range are property set in accordance with the measurement.
  12. Never use meter with wet hands or in a damp environment.
  13. Never use test leads other than the specified test leads.
  14. Never open tester case except when replacing batteries or fuses. Do not attempt any alteration of original specifications.


SPECIFICATIONS
General Specification

Item Specification
Circuit protection The circuit is protected by fuse even when voltage of up to AC 230V is impressed on each range for 5 seconds.
Internal battery R6 (IEC) or UM-3 1.5Vx2, 9V6F22.
Internal fuse 0.5A/250V, Φ5.2mm X 20mm.

Standard calibration temp
And humidity range

23±2℃ 45∽75% RH

Operating temperature
And humidity range.

0∽40℃, 80%RH max. No condensation
Withstand voltage 3kV AC(1min) between input terminal and case.
Dimensions and weight 154x104x34mm 291g(include battery)
Accessories One copy of instruction manual, Test leads


Measurement Range and Accuracy

Function Full scale value Accuracy Remarks
DCV

2.5/10/25/50/250
/1kV

±3%against
full scale

Input impedance
20kΩ/V

ACV 10/50/250/1kV

±4% against
full scale

Input impedance
9kΩ/V

DCA

50μA
0.5/5/50/500mA

±3% against
full scale

*1
Voltage drop 0.1V

10A Voltage drop 0.13V
Ω

x1/x10/x100/x1k
/x10k

±3%of arc Center value 20Ω
DB

-10∽+22d
(for 10V AC)
∽+62dB

_____

Input impedance
9kΩ/V

Beep
HFE 0∽1000

*Not including the resistance of the fuse .

Preparation for Measurement

  1. Adjustment of meter zero position:

Turn the zero position adjuster so that the pointer may align right to the zero position.

  1. Range selection:

Select a range proper for the item to be measured set range selector knob according.

NOTE
When determining a measuring range, select such one for higher voltage then the value to be measured as well as where the pointer of a meter moves to a considerable extent.
However, select the maximum range and measure in case the extent of value to be measured can nor be predicted.

  • Measuring DCV
  1. Set the range selector knob to an appropriate DCV range.
  2. Apply the black test pin to the minus potential of measured circuit and the red test pin to the plus potential.
  3. Read the move of the pointer by DC/AC scale.
Arc Range Multiple Arc Range Multiple
1 X10k X10k 4 DCV250V X1
X1k X1k DCV25V X0.1
X100 X100 DCV2.5V X0.01
X10 X10 ACV250V X1
X1 X1 5 DCA10A X1
2 DCV1000V X1 6 dB
DCV10V X1 ACV10V X1
ACV1000V X1 ACV50V +14
ACV10V X1 ACV250V +28
3 DCV50V X1 ACV1000V +40
ACV50V X1 7 hFE X1
DCA500mA X10
DCA50mA X1
DCA5mA X0.1
DCA0,5mA X0.01
DCA500μA X10

Product Tags:

Digital Pocket Analog Multimeter

      

Pocket Analog Multimeter 10A

      

1000V digital analog meter

      
Quality Digital Pocket Analog Multimeter 10A 1000V With Resistance Function wholesale

Digital Pocket Analog Multimeter 10A 1000V With Resistance Function Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: XI'AN BEICHENG ELECTRONICS CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)